一种空间相机辐射定标用大面积辐射光源的研制
DOI:
CSTR:
作者:
作者单位:

作者简介:

李葆勇(1975-),男,长春市人,副研究 员,主要从事遥感图像辐射校正及空间相机辐射定标的研究.

通讯作者:

中图分类号:

基金项目:

国家“863”高技术研究发展计划基金(863-2-5-1-13B)资助项目 (1.中国科学院长春光学精密机械与物理研究所,吉林 长春 130033; 2.中国科学院大学 ,北京 100049)


Research of large aperture integrating sphere used in the radiative calibration for space remote sensor
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    针对目前空间光学遥感器向着大口径、高精度方向 发展 相应需要大出光面的积分球辐射光源,本文研制了一种大口径空间相机用积分球辐射定标光 源,并使用自制的积分球辐射性能测试装置测试了大口径积分球光 源的均匀性、余弦特性和稳定性。研制的积分球辐射定标光源内径为3000mm,出光面直 径为1000mm。测试结果表明,积分球的最大 幅亮度为240.13W·m-2·sr-1,辐亮度调节范 围为371.5∶1,辐亮度不稳定性为0.04%/h,光源出口面非均匀性为1.7%,辐射定标光源的不确 定度为5%。

    Abstract:

    This paper designs a large aperture in tegrating sphere radiometric source system.The laboratory radiometric calibratio n is an important part during the development of the space optical remote sensor and its effect is to build the response function between input radiance and out put electric signal.This process usually uses an integrting sphere as the radiom etric source.The principle of radiometric calibration follows full aperture,full field of view and end to end.The extended radiometric source is the standard so urce of laboratory radiometric calibration and is required to illuminate the cam era with full aperture and full field of view,so it must have large hatch diamet er and ideal cosine radiation performance.At present,the radiometric calibration device needs a large-scale integrating sphere.Systematically,this paper descri bes the design method and process of a large aperture integrating sphere.We tes t the radiation characteristics of the large aperture integrating sphere,including the uniformity,the stability,the cosine characteristics and the output uncertai nty.The diameter of the integrating sphere is 3000mm and the opening diameter is 1000mm.The test results indicate that t he output uncertainty of this system is 5%.

    参考文献
    相似文献
    引证文献
引用本文

李葆勇,任建伟,万志,李宪圣,刘则洵,孙景旭.一种空间相机辐射定标用大面积辐射光源的研制[J].光电子激光,2013,(3):464~469

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2012-08-27
  • 最后修改日期:2012-10-21
  • 录用日期:
  • 在线发布日期:
  • 出版日期:
文章二维码