基于DOAS的消防应急救援多气体快速遥感仪
DOI:
CSTR:
作者:
作者单位:

(1.天津大学 精密仪器与光电子工程学院,300072; 2.天津市第二中学,300140; 3.天津 市三博科技有限公司,300102; 4.天津市公安局消防局,300090)

作者简介:

姚建铨(1939-),男,出生江苏省,现为天津大学教授、博 士生导师、中国科学院院士,主要从事激光与太赫兹等相关技术研究.

通讯作者:

中图分类号:

基金项目:

天津市科技支撑项目(13ZCZDSF02300)资助项目 (1.天津大学 精密仪器与光电子工程学院,300072; 2.天津市第二中学,300140; 3.天津 市三博科技有限公司,300102; 4.天津市公安局消防局,300090)


Fast multi-gas remote monitor based on DOAS for fire emergency rescue
Author:
Affiliation:

(1.School of Precision Instrument and Optoelectronics Engineering,Tianjin University,Tianjin 300072; 2.Tianjin Second Middle School,300140; 3.Sanbo Technology Co.,Ltd.,Tianjin 300102; 4.Tianjin Municipal Fire Bureau,Tianjin 300090,China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    在国内首次报道了可对30多 种有毒气体连续监测的基于DOAS(differential optical absorption spectra)技术的车载消防应急救援多气体快速遥感仪,仪器采用长光程紫外差分吸收光谱 法痕量气体分析 技术,光发射器和光接收器共用一个卡塞格林望远镜,以减少大气紊动对测量数据的影响; 仪器的反射系 统可以灵活地设置在任意需要区域,分析系统设置在救援车内,在需要长时间监测时,避免 了工作人员近 距离暴露在危险环境中。多气体DOAS仪器特别适合各类气体泄漏事故的消防应急处理。

    Abstract:

    In this paper,a vehicle-mounted fire emergency rescue multi-gas monitor based on DOAS (Differential Optical Absorption Spectra) technology is reported,which can continuously monitor more than 30kinds of poisonous gases.A long path ultraviolet differential absorption spectroscopy method for trace gas analysis is used to realize the continuous monitoring the gas components and the concentrations in the air.Optical transmitter and optical receiver share a Cassegrain telescope,in order that the atmospheric turbulence effects on the measurement data can be reduced.Reflection system can be set in any measurement area flexibly,and analytical system is set in the rescue vehicle,which can avoid the rescue worker exposure in dangerous environment at close range when continuous monitoring is required.Multi-gas DOAS system is especially suitable for fire emergency treatment of various gas leakage accidents.

    参考文献
    相似文献
    引证文献
引用本文

姚建铨,李润宸,赵帆,蔡兆文,王洪兴,徐德刚,张帆,乔旭.基于DOAS的消防应急救援多气体快速遥感仪[J].光电子激光,2018,29(3):314~317

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2017-11-28
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2018-03-28