光纤光栅和静态电阻在静压模型管桩测试中的对比试验研究
DOI:
CSTR:
作者:
作者单位:

(1.青岛理工大学 土木工程学院,山东 青岛 266033; 2.山东省高等学校蓝色经济区工程 建设与安全协同创新中心,山东 青岛 266033)

作者简介:

王永洪(1984-),男,山东东营,博士,讲师,主要从事土 力学和桩基础工程、岩土工程测试方面的研究.

通讯作者:

中图分类号:

基金项目:

国家自然科学基金资助项目(41502304,8,51778312)、山东省重点研 发计划(2017GSF20107)和山东省自然科学 基金项目(ZR2016EEP06)资助项目 (1.青岛理工大学 土木工程学院,山东 青岛 266033; 2.山东省高等学校蓝色经济区工程 建设与安全协同创新中心,山东 青岛 266033)


Research on comparison of fiber Bragg grating and static resistance used in Jacked model pipe pile test
Author:
Affiliation:

(1.School of Civil Engineering,Qingdao University of Technology,Qingdao 266033,China; 2.Collaborative Innovation Center of Engineering Construction and Safety in Shandong Blue Econom ic Zone,Qingdao 266033,China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为了提高光纤布拉格光栅(fiber Bragg gratin g,简称FBG)应变传感器测量精度,针对光纤光栅传 感器在模型管桩试验应用情况,提出了一种光纤光栅传感器理论灵敏度系数和实验灵敏度系 数应变标定方 法。该方法通过实验标定微型光纤光栅应变传感器的灵敏度系数,与理论分析传感器灵敏度 系数进行对比, 同时在模型管桩安装传感器位置粘贴应变片。实验结果表明,标定后的FBG应变传感器测试 结果更加准确, 为基于FBG应变传感器的模型管桩监测技术奠定了基础。同时,该方法适用于FBG传感器应 用与模型管 桩前的标定,可以得到准确反映模型管桩受力变形的真实数据,提高了光纤光栅传感器在模 型管桩试验中 的测量精度。同时,该方法简单、易操作,为光纤光栅传感器在试验和工程中应用奠定了基 础,加快了FBG 传感器在模型管桩荷载传递监测应用的步伐。

    Abstract:

    In order to improve the measurement accuracy of fiber Bragg grating (F BG) strain sensors,a fiber grating sensor theoretical sensitivity coefficient and experimental sensitivity coefficient strain calibration method is proposed in view of the application of FBG sensors in the model pipe pile tes t.The method calibrates the sensitivity coefficient of the micro-gray grating strain sensor by experiment, and compares it with the theoretical analysis sensor sensitivity coefficient.At the same time the strain gauge is pa sted on the model pipe of installing FBG sensor position.The experimental results show that the FBG strain sensor tes t results are more accurate, which lays a foundation for the model tube pile monitoring technology based on F BG strain sensor.At the same time,the method is applicable to the calibration of the FBG sensor application and the model pipe pile,and can obtain the real data accurately reflecting the deformation of the model pipe pil e,and improve the measurement accuracy of the fiber grating sensor in the model pipe pile test.At the same tim e,the method is simple and easy to operate,which lays a foundation for the application of fiber Bragg grating sens ors in testing and engineering,and accelerates the application of FBG sensors in the monitoring and application of model tube pile load transfer.

    参考文献
    相似文献
    引证文献
引用本文

王永洪,张明义,刘雪颖,刘俊伟,赵彦平.光纤光栅和静态电阻在静压模型管桩测试中的对比试验研究[J].光电子激光,2019,30(10):1079~1085

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2019-04-22
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2019-12-04
  • 出版日期:
文章二维码