土壤中Pb、Cr元素激光诱导击穿光谱技术定量分析
DOI:
CSTR:
作者:
作者单位:

(1.河北大学 质量技术监督学院,河北 保定 071000; 2.计量仪器与系统国家地方联合工 程研究中心,河北 保定 071000)

作者简介:

李红莲(1979-),女,河北保定人,博士,副教授,硕士生 导师,主要从事光谱检测技术及其在气体以及固体测量中的应用和可调谐光纤激光器及应用 等方面的研究.

通讯作者:

中图分类号:

基金项目:

河北省自然科学基金重点项目(E2017201142)、河北省博士后科研项目(B2016003008)和击穿光谱与吸收光谱技术 在污水管道中的组合测量研究(CXZZSS2020013)资助项目 (1.河北大学 质量技术监督学院,河北 保定 071000; 2.计量仪器与系统国家地方联合工 程研究中心,河北 保定 071000)


Quantitative analysis of Pb and Cr in soil by laser-induced breakdown spectrosc opy
Author:
Affiliation:

(1.College of Quality and Technology Supervising,Hebei University,Baoding 071000,China; 2.National and local joint engineering center of measuring instrumen ts and metrology systems,Baoding 071000,China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    采用激光诱导击穿光谱技术(Laser-induced b reakdown spectroscopy,LIBS)对土 壤样品中的Pb和Cr元素进行了分析,以PbI280.17 nm和CrI425.43 nm作为分析线,优化了透 镜到样品的距离(Lens to sample distance,LTSD)、延迟时间对光谱信号强度及信噪比 SNR 的影响。在最佳实验条件下,对两种元素的谱峰强度和元素浓度进行分析,针对外标法 和内标法分别建立了谱线峰值强度、谱线峰值积分面积与对应元素浓度的定标曲线。采用谱 线峰值积分面积法对土壤中重金属Pb和Cr元素的检测,相比于外标法,内标法将Pb和Cr元素 最大相对误差分别从13.56%和12.68%降低到了 6.7%;Pb和Cr元素定标曲线的拟合相关 系数R2分别从0.978和0.975提高到了0.996和0.991。实 验结果表明:采用LIBS技术对土 壤中Pb、Cr元素检测具有可行性,采用谱线峰值积分面积的内标法,可以降低最大相对误差 并提高测量精度。

    Abstract:

    Laser-induced breakdown spectroscopy (LIBS) was used to analyze the P b and Cr elements in soil samples.PbI280.17nm and CrI425.43nm were used as the analysis lines,the influence of the lens to sample distance (LTSD)、delay time on the spectral signal intensity and signal-to-noise ratio SNR are optimized.Under the best experimental conditions,the spectral peak intensities and element concentrations of the two elements were analyzed,and the calibratio n curves of the spectral peak intensity and the spectral peak integral area with the corresponding element concentration were established for the external stand ard method and the internal standard method.Compared with the external standard method,the internal standard method reduces the maximum relative errors of the Pb and Cr elements from 13.56% and 12.68% to 6.7% and 5.6% by using the peak in tegral area of the spectrum to detect the heavy metals Pb and Cr in the soil;Th e fitting correlation coefficient R2of Pb and Cr element calibration curves inc reased from 0.9781and 0.9755to 0.9964an d 0.9911respectively.Experimental re sults show that the use of LIBS technology to detect Pb and Cr elements in soil is feasible,and the use of internal standard method of spectral peak integral a rea can reduce the maximum relative error and improve the measurement accuracy.